1.
Journal of Biomedical Engineering ; (6): 357-362, 2015.
Article in Chinese | WPRIM | ID: wpr-266672

ABSTRACT

This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.


Subject(s)
Diagnostic Imaging , Endoscopes , Endoscopy , Software
2.
China Medical Equipment ; (12): 11-12,13, 2013.
Article in Chinese | WPRIM | ID: wpr-598713

ABSTRACT

Objective: To design qualitative quality control testing device for portable medical endoscope optical performance. Methods:To install the mounting bracket, uniform light source and testing target, etc and integrate testing of the visual resolution, geometric distortion, color reproduction capability, the dynamic range and the brightness of the image plane on only one testing target. Results:This kind of device can observe the target by eye or monitor. Conclusion:It can realize the function of rapid, qualitative detection for clinical medical endoscope optical performance parameters.

SELECTION OF CITATIONS
SEARCH DETAIL